Students testing

ICS Transforms

Not all data can be directly measured. An example would be transconductance of MOSFET devices (the derivative of Id with respect to Vg). To create a transform, click on the Transform Editor icon.

The Transform Editor window will open with the active setup as the default setup.

To add a transform, type in a name for the transform in the box labeled Transform: and set it equal to the mathematical expression desired. For example:

gm = DIFF(ID,VG)

The available functions are listed in the function box. You can add the variables measured by selecting the appropriate variable name under Vectors. Common constants are also listed.

Once created, click Save. The transform is then listed in the larger box. When you are done adding transforms, click on Done.

Perform the following tests in order:

  1. MOS Capacitor

  2. PMOSFET

  3. pn Diode

  4. BJT

ICS Reference

  · Introduction

  · Starting

  · File Structure

  · Test Setup

  · Measurements

  · Transforms

  · Plots

IC-CAP Files

  · Tutorial Model

  · Hardware Setup

  · Sample Tutorial Dataset

Data Sheets

  · MTP2955

  · 2N2222A

Adobe Acrobat Reader Link

Link will open in new window Download Adobe Reader to view the files.


Answers provided by this service may not be relevant to the materials presented in this website.

Department of Electrical and Computer Engineering
College of Engineering
University of Illinois Urbana-Champaign

Contact ece444
Copyright ©2017 The Board of Trustees at the University of Illinois. All rights reserved.